MPC HLO (Semi-Hermetic Reciprocating Compressors, 1-stage)
|
|
Semi-Hermetic Reciprocating Compressors
|
Input and pressure control of 0.1Kgf/cm2.
|
|
Oil pump type refrigeration system
|
Auto zero set. convert measured pressure unit (Mpa, bar, psi, kg)
|
|
dual +oil pressure measurement and control systems
|
Condensation an evaporation pressure change temperature.
|
|
1-point low & 2-point high & oil pressure alarm
|
Application of LCD back-light.
|
|
3-point fan control
|
Low high analog out 4~20mA(1~5vdc)
|
|
Relay out cable point of contact
|
RS-485 communication
|
|
MPC HL-H (Capacity Compressor system)
|
|
Scroll tandem type refrigeration system
|
Input and pressure control of 0.1Kgf/cm2.
|
|
Screw pressure Capacity Compressor
|
Auto zero set. convert measured pressure unit (Mpa, bar, psi, kg)
|
|
dual pressure measurement and control systems
|
Condensation an evaporation pressure change temperature.
|
|
2-point low & 1-point high pressure alarm
|
Application of LCD back-light.
|
|
3-point fan control
|
Low high analog out 4~20mA(1~5vdc)
|
|
Relay out cable point of contact
|
RS-485 communication
|
|
MPC HL-L (Capacity Control refrigeration system )
|
|
Capacity compressor valve control
|
Input and pressure control of 0.1Kgf/cm2.
|
|
Screw pressure Capacity Compressor
|
Auto zero set. convert measured pressure unit (Mpa, bar, psi, kg)
|
|
dual pressure measurement and control systems
|
Condensation an evaporation pressure change temperature.
|
|
4-point low & 1-point high pressure alarm
|
Application of LCD back-light.
|
|
water-cooled shell and tube condenser systems
|
Low high analog out 4~20mA(1~5vdc)
|
|
Relay out cable point of contact
|
RS-485 communication
|
|
MPC HLW (chiller unit for air dryer)
|
|
Cooler and air dryer unit control
|
Input and pressure control of 0.1Kgf/cm2.
|
|
Mold chiller Compressor & Water pump systems
|
Auto zero set. convert measured pressure unit (Mpa, bar, psi, kg)
|
|
dual pressure & water pressure control systems
|
Condensation an evaporation pressure change temperature.
|
|
2-point low & 1-point high pressure alarm
|
Application of LCD back-light.
|
|
1-point water pressure & 2-point fan control
|
Low high analog out 4~20mA(1~5vdc)
|
|
Relay out cable point of contact
|
RS-485 communication
|
|
MPC HLOM (Semi-Hermetic Reciprocating Compressors, 2-stage)
|
|
Very low temperature Freezer
|
Input and pressure control of 0.1Kgf/cm2.
|
|
4 port cold store compressor controller
|
Auto zero set. convert measured pressure unit (Mpa, bar, psi, kg)
|
|
Low & middle pressure control systems
|
Condensation an evaporation pressure change temperature.
|
|
1-point low, high, oil pressure alarm
|
Application of LCD back-light.
|
|
oil + middle pressure comparator control
|
Low high analog out 4~20mA(1~5vdc)
|
|
Relay out cable point of contact
|
RS-485 communication
|
|
MPC –HLOW (for chiller and air dryer for enclosed freezer)
|
|
Semi-Hermetic Compressors + water pump
|
Auto zero set. convert measured pressure unit (Mpa, bar, psi, kg)
|
|
Chiller pressure control systems
|
Condensation an evaporation pressure change temperature.
|
|
1-point low, high, oil pressure alarm
|
Application of LCD back-light.
|
|
oil + low pressure comparator control
|
Low high analog out 4~20mA(1~5vdc)
|
|
Relay out cable point of contact
|
RS-485 communication
|